The Dixell XR60CX is a microprocessor-based digital controller‚ designed for use in medium and low temperature ventilated refrigeration units. This controller offers digital control with defrost and fan management‚ ensuring efficient operation.

Overview of the Dixell XR60CX

The Dixell XR60CX controller is a versatile device suitable for a range of refrigeration applications‚ particularly in medium and low-temperature environments. It is a microprocessor-based controller‚ ensuring precise and reliable operation. The controller is designed with a compact 71×29 mm format‚ making it easy to integrate into various refrigeration units. It provides essential functions like temperature control‚ defrost management‚ and fan operation. Different models are available‚ such as the XR60CX-4N1F1 for 120V‚ XR60CX-5N1F1 for 230V‚ and XR60CX-AN1F1 for 12/24V power supplies. The XR60CX also features a HOT KEY port for external communication‚ enabling connection to monitoring systems. This controller is an excellent choice for those seeking a robust and efficient solution for their refrigeration needs‚ offering both digital precision and user-friendly features.

Key Features and Benefits

The Dixell XR60CX offers digital control‚ managing defrost cycles and fan operations effectively. It is suitable for both medium and low-temperature refrigeration‚ providing versatile application in diverse settings.

Digital Control with Defrost and Fan Management

The Dixell XR60CX excels in providing precise digital control over refrigeration systems. Its defrost management capabilities ensure efficient operation by automatically initiating defrost cycles‚ preventing ice buildup and maintaining optimal performance. Additionally‚ the controller offers advanced fan management‚ allowing for various fan control modes‚ including running with the compressor or cycling on and off independently. This flexibility enables users to optimize energy consumption and maintain consistent temperatures. Furthermore‚ the XR60CX’s digital interface makes monitoring and adjustments straightforward‚ enhancing overall system reliability and ease of use. This integrated approach to control streamlines the operation of refrigeration units.

Suitable for Medium and Low Temperature Refrigeration

The Dixell XR60CX is specifically designed to cater to the requirements of both medium and low temperature refrigeration systems. Its versatile design allows it to function effectively in a wide array of applications‚ ranging from commercial refrigerators and freezers to more specialized cooling systems. The controller’s precise temperature management ensures optimal conditions for preserving a variety of products. Its ability to handle varied temperature ranges makes it a reliable choice for maintaining the integrity of perishable goods. This adaptability makes the XR60CX an ideal solution for diverse refrigeration needs‚ providing accurate control and efficient performance across different temperature requirements. Its robust build guarantees long-term reliable operation.

Operating Instructions

Operating the Dixell XR60CX involves using the front panel commands for navigation and settings adjustments. Key functions include initiating manual defrost and modifying parameter values.

Front Panel Commands and Navigation

The Dixell XR60CX’s front panel provides intuitive controls for easy operation. The “SET” key is used to access and confirm settings. Navigation through the menu is achieved using the “UP” and “DOWN” arrow keys. To initiate a manual defrost cycle‚ the “DEF” key is pressed and held for more than two seconds. The display shows current temperature and status indicators. Understanding the symbols and icons on the display is crucial for correct operation. The front panel also allows access to parameter configuration‚ which involves pressing a combination of keys for a set period. The clear layout makes it easy to manage the controller effectively. The user should consult the manual for specific details on each key’s function. Proper use of these commands ensures optimal control of the refrigeration system‚ contributing to its efficient performance and longevity.

Manual Defrost Procedure

Initiating a manual defrost on the Dixell XR60CX is a straightforward process. To begin a manual defrost cycle‚ press and hold the “DEF” key‚ typically identified by a snowflake symbol‚ for more than two seconds. This action overrides the automatic defrost settings and starts a defrost cycle immediately. The controller display will indicate the defrost process is active. During defrost‚ the compressor and fans may be turned off to allow the evaporator coil to thaw. It’s important to ensure that the defrost cycle completes successfully to prevent any build-up of ice. Once the defrost is complete‚ the controller will return to normal operation. This manual defrost procedure can be used to address situations where excessive ice has accumulated or when a scheduled defrost is not sufficient.

Parameter Configuration

The Dixell XR60CX allows users to configure various parameters. Accessing these parameters requires entering a programming mode. Adjustments can be made for optimal system performance and control.

Accessing and Changing Parameters

To access the parameter configuration menu on the Dixell XR60CX‚ press the “Set” and “Down” keys simultaneously for three seconds. The unit will then enter programming mode‚ indicated by a blinking LED‚ either ‘C’ or ‘F’. Release the keys and then press “Set” and “Down” again for more than seven seconds. This will display the “Pr2” label‚ followed by the “HY” parameter. Navigate through the parameters using the “Up” and “Down” keys. To modify a parameter‚ select it‚ then use the “Up” and “Down” keys to adjust the value. Once the desired value is set‚ press the “Set” key to confirm and store the changes. This process allows for customized operation tailored to specific refrigeration needs. Remember to consult the full manual for detailed parameter descriptions and appropriate ranges.

Fan Control Settings

The Dixell XR60CX offers versatile fan control settings to optimize refrigeration performance. Fan operation can be configured using specific parameters‚ like ‘Fon’ and ‘FoF’. Fans can run in parallel with the compressor‚ switching on and off together‚ or they can be set to cycle independently‚ even when the compressor is not running. This is achieved by setting the relevant parameters. The controller also allows the fans to be deactivated during the defrost cycle‚ which prevents unnecessary air circulation; The selected fan control mode is determined by parameters‚ allowing for customized settings that best match your specific application. Understanding these parameters ensures proper airflow and temperature management in the refrigeration system. Proper setup is essential.

Troubleshooting

The Dixell XR60CX has a watchdog function for data integrity. Error codes‚ like P2‚ indicate probe issues. Alarms will sound‚ signaling operational problems that require attention to resolve.

Understanding Error Codes (e.g.‚ P2 Evaporator Probe Failure)

The Dixell XR60CX utilizes error codes to communicate operational issues‚ with “P2” specifically indicating an evaporator probe failure. This error suggests that the controller is not receiving a valid temperature reading from the evaporator probe‚ which could stem from a faulty connection or a malfunctioning probe. When this error appears‚ it’s crucial to first check the physical connection of the probe to the controller‚ ensuring it is securely attached. If the connection is sound‚ the probe itself may need to be replaced. Ignoring this error can lead to improper defrost cycles and temperature control‚ negatively impacting the refrigeration unit’s performance. The controller’s ability to signal these issues via error codes helps in the timely identification and resolution of problems.

Alarm Indications and Watchdog Function

The Dixell XR60CX controller features a built-in alarm system to alert users to potential issues. These alarms are typically indicated by a flashing visual signal on the display and an audible buzzer‚ ensuring that problems are promptly addressed. In addition to the standard alarms‚ the XR60CX also incorporates a watchdog function that continuously monitors the controller’s data and memory integrity. This watchdog acts as a safety mechanism‚ verifying that all stored parameters and operational data remain consistent. If any discrepancies are detected‚ the watchdog will trigger an alarm‚ indicating the potential for a fault within the controller. This alarm system helps prevent errors during operation and ensures the integrity of the refrigeration process. This dual approach of alarms and watchdog enhances overall system reliability.